Results 1 - 20 de 1.176
Filter
1.
Appl Radiat Isot ; 208: 111307, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38564840

ABSTRACT

Early works that used thermoluminescent dosimeters (TLDs) to measure absorbed dose from alpha particles reported relatively high variation (10%) between TLDs, which is undesirable for modern dosimetry applications. This work outlines a method to increase precision for absorbed dose measured using TLDs with alpha-emitting radionuclides by applying an alpha-specific chip factor (CF) that individually characterizes the TLD sensitivity to alpha particles. Variation between TLDs was reduced from 21.8% to 6.7% for the standard TLD chips and 7.9% to 3.3% for the thin TLD chips. It has been demonstrated by this work that TLD-100 can be calibrated to precisely measure the absorbed dose to water from alpha-emitting radionuclides.


Subject(s)
Radiation Dosimeters , Thermoluminescent Dosimetry , Thermoluminescent Dosimetry/methods , Radioisotopes , Radiometry/methods , Calibration
2.
Radiat Prot Dosimetry ; 200(5): 481-486, 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38324740

ABSTRACT

The performance of two thermoluminescent dosimetry systems (RGD-3D and RE2000) manufactured in China and Finland was compared. Both of these dosimetry systems demonstrated satisfactory results as their performance met the requirements of the standard. The two dosimetry systems showed similar performance in the energy response. The RGD-3D dosimetry system performed better in nonlinear response, minimum detectable level and blind sample tests, whereas the RE2000 dosimetry system showed better stability.


Subject(s)
Photons , Thermoluminescent Dosimetry , Thermoluminescent Dosimetry/methods , Radiometry/methods , Oligopeptides , China
3.
Luminescence ; 39(2): e4683, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38332469

ABSTRACT

This work explores the thermoluminescence (TL) and photoluminescence (PL) properties of Ag/Y co-doped zinc oxide (ZnO) nanophosphor. The proposed dosimeter was prepared by the coprecipitation method and sintered at temperatures from 400°C to 1000°C in an air atmosphere. Raman spectroscopy was studied to investigate the structural features of this composition. The new proposed dosimeter revealed two peaks at 150°C and 175°C with a small shoulder at high temperature (225°C). The PL spectrum showed strong green emissions between 500 to 550 nm. The Raman spectrum showed many bands related to the interaction between ZnO, silver (Ag), and yttrium oxide (Y2 O3 ). The rising sintering temperature enhanced the TL glow curve intensity. The Ag/Y co-doped ZnO nanophosphor showed an excellent linearity index within a dose from 1 to 4 Gy. The minimum detectable dose (MDD) of the Ag/Y co-doped ZnO nanopowder (pellets) equaled 0.518 mGy. The main TL properties were achieved in this work as follows: thermal fading (37% after 45 days at 1 and 4 Gy), optical fading (53% after 1 h and 68% after 6 h by exposure to sunlight), effective atomic number (27.6), and energy response (flat behavior from 0.1 to 1.3 MeV). Finally, the proposed material shows promising results nominated to be used for radiation measurements.


Subject(s)
Zinc Oxide , Temperature , Thermoluminescent Dosimetry/methods , Silver/chemistry
4.
Radiat Prot Dosimetry ; 200(4): 423-427, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38195760

ABSTRACT

The effect of natural rapid cooling and oven slow cooling on the precision of thermoluminescence measurements of LiF:Mg,Ti is investigated. Three separate series of measurements resulted in average precisions of 5.1 and 5.0%, respectively. However, the highest precision of 1.7% (1 SD) was achieved for an oven-cooled material.


Subject(s)
Lithium Compounds , Thermoluminescent Dosimetry , Thermoluminescent Dosimetry/methods , Fluorides , Titanium , Equipment Design
5.
Luminescence ; 39(1): e4679, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38286606

ABSTRACT

In this work, (99 - x)CaSO4 -Dy2 O3 -xEu2 O3 , (where x = 0, 0.05, 0.1, 0.2, 0.3, 0.4, 0.5) thermoluminescence phosphors were prepared using a coprecipitation method. The thermoluminescence (TL) dosimetry (TLD) characteristics such as TL sensitivity, dose-response, minimum detectable dose, thermal fading, and the effect of sunlight on the prepared phosphors were investigated. The obtained results indicated that the most sensitive phosphor was obtained at x = 0.05. Large thermal fading of 6% after 1 h and 26% after 24 h from irradiation followed by 71% after 1 month with no additional fading was observed within a time frame exceeding 2 months throughout the remaining duration of the investigation, which also spanned over 2 months. Despite the phosphor's high fading rate, the relative sensitivity of the prepared samples was ~90% compared with TLD-100. The marked effect of day sunlight was also determined. High dose-response within the low-dose range from 0.01 to 5 Gy was observed. The obtained results suggested that the synthesized phosphor is well suited for applications involving radiation biology and radiotherapy dosimetry.


Subject(s)
Dysprosium , Thermoluminescent Dosimetry , Thermoluminescent Dosimetry/methods
6.
Radiat Res ; 200(6): 569-576, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-37931289

ABSTRACT

In this study, the preparation and characterization of copper (Cu) and terbium (Tb) co-doped lithium borate glass using spectroscopic and thermoluminescence techniques are reported. A thermal treatment was introduced to increase the degree of crystallinity. The thermoluminescence glow curve signal of the samples displayed upon exposure to beta radiation was measured and analyzed. It was found that the samples doped with 0.1% of copper and co-doped with 0.3% terbium showed the highest thermoluminescent (TL) signal in response to the irradiated dose. The analyses revealed that the glow curves of the doped samples were composed of nine overlapping glow peaks with activation energies between 0.73 and 2.78 eV. As a whole area under the glow curve, the TL signals displayed a linear dose response in the range from 110 mGy to 55 Gy. The minimum detectible dose of the samples was found to be 10.39 µGy. It was found that peaks 1 and 2 disappear after one day of storage. The rest of the peaks (3-9) remain almost constant up to 74 days of storage.


Subject(s)
Copper , Terbium , Copper/chemistry , Terbium/chemistry , Thermoluminescent Dosimetry/methods
7.
Radiat Prot Dosimetry ; 199(15-16): 1818-1823, 2023 Oct 11.
Article in English | MEDLINE | ID: mdl-37819281

ABSTRACT

Extremity radiation monitoring is an important tool for the assessment of occupational exposures to staff at a variety of workplaces where ionising radiation is used. This work shows the feasibility of applying 3D printing for the development of customisable ring dosemeters. The rings were developed using two types of resin, hard and flexible and has the possibility of sterilisation using different techniques. The printed ring dosemeter was associated with BeO optically stimulated dosemeters. The energy and angular response were found within ±20% in the energy range from 24 to 662 keV and from 0° to 60° angle of incidence. This contributes to the reduction of measurement uncertainty when compared with currently used thermoluminescent detectors dosemeters. The new ring dosemeter showed a satisfactory response with respect to the performance criteria of the IEC 62387 Standard, in addition to providing improved ergonomics in relation to the commercial ring dosemeter.


Subject(s)
Occupational Exposure , Radiation Monitoring , Humans , Radiation Dosage , Radiation Monitoring/methods , Radiation Dosimeters , Protective Devices , Occupational Exposure/analysis , Printing, Three-Dimensional , Thermoluminescent Dosimetry/methods
8.
Radiat Res ; 200(4): 357-365, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37702413

ABSTRACT

Significant past work has identified unexpected risks of central nervous system (CNS) exposure to the space radiation environment, where long-lasting functional decrements have been associated with multiple ion species delivered at low doses and dose rates. As shielding is the only established intervention capable of limiting exposure to the dangerous radiation fields in space, the recent discovery that pions, emanating from regions of enhanced shielding, can contribute significantly to the total absorbed dose on a deep space mission poses additional concerns. As a prerequisite to biological studies evaluating pion dose equivalents for various CNS exposure scenarios of mice, a careful dosimetric validation study is required. Within our ultimate goal of evaluating the functional consequences of defined pion exposures to CNS functionality, we report in this article the detailed dosimetry of the PiMI pion beam line at the Paul Scherrer Institute, which was developed in support of radiobiological experiments. Beam profiles and contamination of the beam by protons, electrons, positrons and muons were characterized prior to the mice irradiations. The dose to the back and top of the mice was measured using thermoluminescent dosimeters (TLD) and optically simulated luminescence (OSL) to cross-validate the dosimetry results. Geant4 Monte Carlo simulations of radiation exposure of a mouse phantom in water by charged pions were also performed to quantify the difference between the absorbed dose from the OSL and TLD and the absorbed dose to water, using a simple model of the mouse brain. The absorbed dose measured by the OSL dosimeters and TLDs agreed within 5-10%. A 30% difference between the measured absorbed dose and the dose calculated by Geant4 in the dosimeters was obtained, probably due to the approximated Monte Carlo configuration compared to the experiment. A difference of 15-20% between the calculated absorbed dose to water at a 5 mm depth and in the passive dosimeters was obtained, suggesting the need for a correction factor of the measured dose to obtain the absorbed dose in the mouse brain. Finally, based on the comparison of the experimental data and the Monte Carlo calculations, we consider the dose measurement to be accurate to within 15-20%.


Subject(s)
Mesons , Animals , Mice , Radiometry/methods , Protons , Central Nervous System , Monte Carlo Method , Thermoluminescent Dosimetry/methods , Water , Phantoms, Imaging
9.
Article in English | MEDLINE | ID: mdl-37625926

ABSTRACT

OBJECTIVES: We aimed to map the correlation between thermoluminescent dosimeters (TLDs) and Gafchromic film for measuring absorbed doses and to compare minimum, maximum, and mean absorbed doses over larger regions of interest and at various craniofacial organs and tissues during cone beam computed tomography (CBCT) exposure of the mandibular third molar region. STUDY DESIGN: We positioned TLDs at 75 measurement points in a head phantom. Gafchromic film was cut to the same shape as the 5 levels of the phantom and was placed on top of the TLDs. Both dosimetry methods thus included the surface of each level simultaneously. CBCT scans were made using a 5 × 5 cm field of view and a rotation angle of 200°. Measurements included absorbed dose distributions, doses at all 75 points, and minimum, maximum, and mean doses within organs and tissues. RESULTS: The correlation of point-dose measurements at all TLD sites with doses measured on film was strong (R2 = 0.9687), with greatest correlation at lower doses (<2 mGy). Large deviations between TLD and film measurements of minimum and maximum doses and absorbed doses to the organs occurred at all 5 levels. TLD positioning failed to cover several organ sites; for these, only absorbed dose measurements from the film were available. CONCLUSIONS: TLDs were unable to sample dose distributions and gradients accurately. The characteristics of Gafchromic LD-V1 film make it a favorable alternative in dental CBCT dosimetry.


Subject(s)
Radiation Dosimeters , Thermoluminescent Dosimetry , Humans , Radiation Dosage , Thermoluminescent Dosimetry/methods , Cone-Beam Computed Tomography/methods , Mandible/diagnostic imaging , Phantoms, Imaging
10.
Luminescence ; 38(10): 1780-1788, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37491134

ABSTRACT

This study reports the thermoluminescence (TL) aspects of Ca10 K(PO4 )7 :Dy phosphor synthesized using a wet chemical method for the first time. The X-ray diffraction (XRD) results confirm the formation of the desired crystalline phase. Surface morphological studies reveal the formation of polyhedrons and agglomerations having an average diameter of 200 nm, while energy dispersive X-ray spectroscopy (EDS) data show the presence and composition of the elements in appropriate amounts. The effect of Dy doping concentration has been studied on the TL properties with exposure to gamma radiations from the Co-60 source. The best TL response has been observed for 5 mol% Dy doping concentration. The glow curve is simple and consists of a single peak at 130°C. The effect of the heating rate has been studied on the TL glow curve, and the heating rate of 5°C/s shows the best TL response. The various TL properties such as annealing conditions, dose-response, TL linearity, fading, and reusability of the prepared phosphor have been studied to check its suitability as a good TL dosimeter (TLD). TL characterization of the phosphor reports that the TL response is linear from 5- to 2000 Gy. The results show that this phosphor can be a good TLD for the dosimetry of gamma radiations from Co-60.


Subject(s)
Radiation Dosimeters , Thermoluminescent Dosimetry , Thermoluminescent Dosimetry/methods , Gamma Rays , Radiometry
11.
Phys Med Biol ; 68(15)2023 07 21.
Article in English | MEDLINE | ID: mdl-37336242

ABSTRACT

Objective.This work investigates the use of Al2O3:C and Al2O3:C,Mg optically stimulated luminescence (OSL) detectors to determine both the dose and the radiation quality in light ion beams. The radiation quality is here expressed through either the linear energy transfer (LET) or the closely related metricQeff, which depends on the particle's speed and effective charge. The derived LET andQeffvalues are applied to improve the dosimetry in light ion beams.Approach.OSL detectors were irradiated in mono-energetic1H-,4He-,12C-, and16O-ion beams. The OSL signal is associated with two emission bands that were separated using a pulsed stimulation technique and subjected to automatic corrections based on reference irradiations. Each emission band was investigated independently for dosimetry, and the ratio of the two emission intensities was parameterized as a function of fluence- and dose-averaged LET, as well asQeff. The determined radiation quality was subsequently applied to correct the dose for ionization quenching.Main results.For both materials, theQeffdeterminations in1H- and4He-ion beams are within 5 % of the Monte Carlo simulated values. Using the determined radiation quality metrics to correct the nonlinear (ionization quenched) detector response leads to doses within 2 % of the reference doses.Significance.Al2O3:C and Al2O3:C,Mg OSL detectors are applicable for dosimetry and radiation quality estimations in1H- and4He-ions. Only Al2O3:C,Mg shows promising results for dosimetry in12C-ions. Across both materials and the investigated ions, the estimatedQeffvalues were less sensitive to the ion types than the estimated LET values were. The reduced uncertainties suggest new possibilities for simultaneously estimating the physical and biological dose in particle therapy with OSL detectors.


Subject(s)
Linear Energy Transfer , Optically Stimulated Luminescence Dosimetry , Aluminum Oxide , Radiometry/methods , Luminescence , Ions , Thermoluminescent Dosimetry/methods
12.
Appl Radiat Isot ; 198: 110850, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37207370

ABSTRACT

Ionizing radiation dosimetry with thermoluminescence (TL) materials based on silicon or glass can be interesting in its potential use in radiation monitoring as the solution to the constant looking of development of new radiation detectors. In this work, TL characteristics of sodium silicate exposed to beta radiation effects were studied. TL response beta irradiated exhibited a glow curve with two peaks centered at 398 K and 473 K. Samples showed linearity from 0.55 to 13.2 Gy. TL readings after 10 times showed a repeatability with an error of less than 1%. Remain information showed significant losses during the first 24 h, but its information was almost constant after 72 h of storage. The Tmax-Tstop method exhibited three peaks which were mathematically analyzed with a general order deconvolution finding kinetic orders close to the second order for the first peak, meanwhile the kinetic order for the second peak and third peak are close to second order. Finally, the VHR method showed anomalous TL glow curve behavior with an increasing intensity TL as the heating rate increased.


Subject(s)
Silicon , Thermoluminescent Dosimetry , Kinetics , Thermoluminescent Dosimetry/methods
13.
Radiat Prot Dosimetry ; 199(6): 498-508, 2023 Apr 19.
Article in English | MEDLINE | ID: mdl-36856703

ABSTRACT

A seeming contradiction in the prediction of the spatially correlated trapping center/luminescent center model applied to LiF:Mg,Ti has been the linear/supralinear behavior of the dose response of glow peak 5a. In the TC/LC model, the localised electron-hole recombination, giving rise to glow peak 5a, is expected to result in an extended region of linear dose response. Deconvolution of the glow curves based on first order kinetic peak shapes results, however, in a dose response of peak 5a, which closely resembles the linear/supralinear dose response of peak 5. It is demonstrated herein that when general-order kinetics peak shapes are used for peak 5a, the analysis can result in a linear dose response of glow peak 5a up to dose levels as high as 30 Gy, well beyond the 1-Gy onset of supralinearity of peak 5. The extended linearity suggests a resolution of the contradiction.


Subject(s)
Fluorides , Thermoluminescent Dosimetry , Radiation Dosage , Kinetics , Thermoluminescent Dosimetry/methods , Lithium Compounds , Titanium
14.
Phys Med Biol ; 68(4)2023 02 17.
Article in English | MEDLINE | ID: mdl-36696696

ABSTRACT

Objective.This work aims at characterizing LiF:Mg,Ti thermoluminescence detectors (TLDs) for dosimetry of a 250 MeV proton beam delivered at ultra-high dose rates (UHDR). Possible dose rate effects in LiF:Mg,Ti, as well as its usability for dosimetry of narrow proton beams are investigated.Approach.LiF:Mg,Ti (TLD-100TMMicrocubes, 1 mm × 1 mm × 1 mm) was packaged in matrices of 5 × 5 detectors. The center of each matrix was irradiated with single-spot low-LET (energy >244 MeV) proton beam in the (1-4500) Gy s-1average dose rates range. A beam reconstruction procedure was applied to the detectors irradiated at the highest dose rate (Gaussian beam sigma <2 mm) to correct for volumetric averaging effects. Reference dosimetry was carried out with a diamond detector and radiochromic films. The delivered number of protons was measured by a Faraday cup, which was employed to normalize the detector responses.Main results.The lateral beam spread obtained from the beam reconstruction agreed with the one derived from the radiochromic film measurements. No dose rates effects were observed in LiF:Mg,Ti for the investigated dose rates within 3% (k= 1). On average, the dose response of the TLDs agreed with the reference detectors within their uncertainties. The largest deviation (-5%) was measured at 4500 Gy s-1.Significance.The dose rate independence of LiF:Mg,Ti TLDs makes them suitable for dosimetry of UHDR proton beams. Additionally, the combination of a matrix of TLDs and the beam reconstruction can be applied to determine the beam profile of narrow proton beams.


Subject(s)
Protons , Radioactivity , Titanium , Thermoluminescent Dosimetry/methods , Radiometry/methods
15.
Radiat Prot Dosimetry ; 199(1): 1-10, 2023 Jan 04.
Article in English | MEDLINE | ID: mdl-36309853

ABSTRACT

The peak 5 in LiF: Mg, Ti includes sub-peaks 5a and 5b, which occur at the temperatures lower and higher than that of peak 5, respectively. Peak 5a in LiF:Mg,Ti occurs due to the localized recombination of trapping/luminescence center (TC/LC), in which the electron is released from the electron trap by obtaining energy from heat and recombines through the tunneling phenomenon with a hole located in the adjacent luminescence center at a distance of 3 nm. Concerning the standard TLD tablets, which are composed of micron-sized particles, the peak 5a either does not occur or appears with very low intensity, which is insignificant in terms of dosimetry. Thus, the present study focuses on synthesizing thermoluminescent nanoparticles by co-precipitation method in several stages by citing models based on the maintenance of linear behavior of thermoluminescence nanopowders up to high doses and its relationship with localized electron-hole recombination. In addition, by changing the concentration of ingredients, altering the temperature of the reaction medium and presence or absence of surfactant, nanoparticles with suitable geometric shapes were achieved. The synthesized nanopowders were irradiated with different doses of alpha and gamma, and after analyzing the glow curves, the increase in peak 5a/5 was reported as the main factor in nanodosimetry. Based on the results, the LiF: Mg, Ti thermoluminescence nanopowders can increase the 5a/5 ratio and can be used as a convenient, inexpensive and practical tool to estimate the amount of energy deposited by the beams in nanoscale.


Subject(s)
Nanoparticles , Thermoluminescent Dosimetry , Gamma Rays , Thermoluminescent Dosimetry/methods , Fluorides , Lithium Compounds , Titanium
16.
Appl Radiat Isot ; 192: 110580, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36462301

ABSTRACT

Significant research is being conducted on new materials suitable for dosimetry in recent decades with particular focus on their luminescent properties. For instance, a new ceramic detector, aluminum oxide 520 (ALOX-520), was developed at CDTN in 2011 using the sol-gel method. The detectors were doped with C, Fe, Mg, Ca, Cr, Ni, and Mo impurities that generated the necessary dosimetric trap levels to enhance the luminescence effects. Consequently, the resultant material was appropriate for the quantification of ionizing radiation fields by both thermally and optically stimulated luminescence techniques. Originally, ALOX 520 was sintered at 2023 K under a highly reducing atmosphere. At the end of this process, it exhibited important dosimetric properties, as already described in existing literature. The objective of this study is to conduct tests at higher temperatures in vacuum to investigate the effect of thermal treatments under these conditions on the structural and dosimetric properties of the material. Accordingly, ALOX-520 was re-sintered at high temperatures and the changes in its physical, morphological, and dosimetric properties were analyzed. ALOX 520T exhibited better dosimetric properties in terms of homogeneity, reproducibility, linearity, and signal fading. Physically, an increase in the detection threshold value of ALOX-520T could be linked to a decrease in the sensitivity of this detector. The energy dependence, the thermal quenching correction, and kinetic studies for ALOX-520T conducted as part of this work are original. However, the obtained results are consistent with those reported in the literature for α-Al2O3 ceramic detectors. XRD and XRF analyses demonstrated that the thermal treatment did not change the crystalline structure or composition of the material. All the results indicate that an appropriate thermal treatment could improve the dosimetric properties of the ALOX-520 detector without causing significant changes in its crystalline structure.


Subject(s)
Aluminum Oxide , Radiometry , Aluminum Oxide/chemistry , Reproducibility of Results , Kinetics , Luminescent Measurements , Thermoluminescent Dosimetry/methods
17.
Radiat Prot Dosimetry ; 199(2): 116-123, 2023 Feb 15.
Article in English | MEDLINE | ID: mdl-36448827

ABSTRACT

Thermoluminescence dosimetry is considered as an effective method in estimating the absorbed doses to organs in different imaging modalities. The present study focuses on dosimetry in dual-energy X-ray absorptiometry scans, for patients, and phantoms in various imaging centres. The cubical LiF (Mg, Ti) thermoluminescence dosemeters were inserted inside the holes of the Rando phantom slabs, to measure the absorbed dose to different organs in the whole body and lumbar scans. According to the results the maximum entrance skin dose was found to be 202.06 µGy for Hologic discovery W, which uses the fan beam scanning mode. The Norland XR-800 device took the scans with a much lower dose, as it uses the pencil beam for scanning the patients. The results of the study show that the radiation beam type, patient thickness, imaging technique and scan time may affect the radiation dose received by patient.


Subject(s)
Radiometry , Thermoluminescent Dosimetry , Humans , Absorptiometry, Photon , Radionuclide Imaging , Phantoms, Imaging , Thermoluminescent Dosimetry/methods , Radiation Dosage
18.
Appl Radiat Isot ; 191: 110533, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36332424

ABSTRACT

A potentially tissue-equivalent dosimeter based on lithium tetraborate co-doped with Cu and In was successfully synthesized in two steps melting process. Basic material properties were characterized using Differential scanning calorimetry, X-ray diffraction, and Fourier Transform Infrared Spectroscopy, the dosimetric properties using Thermoluminescence. The highest sensitivity was observed for dopant concentrations of 0.1% Cu and 0.5% In. Tmax-Tstop analysis revealed the existence of eight individual peaks in the composite TL glow curve, which was confirmed by computerized glow curve deconvolution. A linear dose-response was seen up to about 30 Gy, for higher doses saturation effects occurred. The minimum detectable dose was estimated at about 670 µGy. TL peaks, with peak temperature above 150 °C faded to values between 3.3 and 14.9% of the respective of initial values after 70 days storage.


Subject(s)
Borates , Thermoluminescent Dosimetry , Thermoluminescent Dosimetry/methods , Borates/chemistry , X-Ray Diffraction , Radiometry
19.
Appl Radiat Isot ; 191: 110549, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36343580

ABSTRACT

In this work, SrGd2O4 phosphors incorporated with Eu3+ at various dopant concentrations are synthesized via solid state reaction method. An X-ray diffraction (XRD) and thermoluminescence (TL) technique were used to examine the structural and thermoluminescent properties of as-prepared phosphors. Orthorhombic phase formation of Eu3+ doped samples was confirmed by XRD. The influence of impurity concentration and heating rates on the glow curves was also investigated. Anomalous heating rate pattern was observed in the sample with Eu3+ additive. A model of semi-localized transition was used to explain this behaviour. The TL glow curves of beta irradiated SrGd2O4:Eu3+ (0.25 mass %) reveal three well-resolved peaks at 105, 189, and 245 °C. Various heating rates, TM-Tstop, initial rise, and computerized glow curve deconvolution techniques were employed to detect the overlapping peak numbers and establish the kinetic parameters of SrGd2O4:Eu3+ (0.25 mass %). When the trap numbers and comparable energy values are considered, the findings of the approaches are very similar. For the dose ranges between 0.1 and 8 Gy, SrGd2O4:Eu3+ (0.25 mass %) samples exhibited linear behaviour, and high reproducibility, indicating their applicability for TL dosimetry applications.


Subject(s)
Europium , Strontium , Europium/chemistry , Reproducibility of Results , Gamma Rays , Thermoluminescent Dosimetry/methods
20.
Front Public Health ; 10: 969330, 2022.
Article in English | MEDLINE | ID: mdl-36187614

ABSTRACT

Screen protector glasses are often used to protect the display screen surface of mobile phones against physical damage. Their dosimetric properties were recently studied by thermoluminescence with the aim of using these items as potential emergency dosimeters in the event of a radiological accident. They are sensitive to ionizing radiation and they could be easily removed and replaced without destroying the phone in case of a dose assessment. However, an intrinsic background signal that partially overlaps with the radiation-induced TL signal is observed. The reconstructed dose could be overestimated if not properly taken into account. The homogeneity of this confounding signal on the surface of several screen protectors was estimated and a chemical treatment with hydrofluoric acid (HF 40%) was tested to minimize its contribution. For most of the samples studied, the intrinsic background signal remained a serious issue for dose reconstruction. Additionally, the TL signals were measured in the red detector range using two different models of red-sensitive photomultiplier tubes. The homogeneity of the intrinsic background signal on the surface of screen protectors was examined and the results of the reduction of this signal by the chemical HF treatment were discussed.


Subject(s)
Cell Phone , Thermoluminescent Dosimetry , Glass/chemistry , Hydrofluoric Acid , Radiation, Ionizing , Thermoluminescent Dosimetry/methods